Instruction manual

SimradPISeineSounder
Aboutsensorconguration
AllsensorsareprovidedfromSimradwithpredened
communicationchannelsandupdaterates.
Defaultcommunicationchannelsand
updaterates
Seethetablebelowfortheinitialvaluesforthecommunication
channelsandupdateratesforthevarioussensors.
Table1Defaultcommunicationchannelsandupdaterates
SensorCom.channel(s)
Updaterate
PIBottomContact
6Normal
PICatch
4Normal
PIDepthDepth300M:16
Depth600M:12
Depth1000M:10
Fast
PIHeight14Fast
PIRemote/Depth
Depth300M:11
Depth600M:15
Depth1000M:13
Fast
PISpread
2Fast
PISpread/Depth
Depth300M:16
Depth600M:12
Depth1000M:10
Spread:2
Fast
PITwinSpread
2and7Fast
PITemperature8Fast
PIGeometry
1and5Fast
PISeineSounder
Depth300M:5
Depth600M:9
Depth1000M:1
Height:14
Fast
Changingacommunicationchannel
Itmayberequiredtochangeoneormorecommunication
channels,andtheremaybemanyreasonsforthis.
Youhavemorethanoneofeachsensor.Forexample,ifyou
havethreetemperaturesensors,theyMUSTcommunicate
onthreedifferentchannels.
OthervesselsnearyourusethesamePIcatchmonitoring
system(orasimilar),andtheyhaveoneormoreoftheir
sensorssetuptothesamecommunicationchannelsasyou
have.Thiswillcreateinterference,asyouwill"read"each
otherssensors.
20
313700/D