Instruction manual
Simrad PI Remote/Depth
Figure 10 Graphical presentation on PI44/PI54
17.5 12.5
10
7.5
5
2.5
15
min
38kHz 1000W MEDIUM
T 22.5 C
o
S 7.2kn DK 1050 m
(CD012106F)
D1[m]
167
5
0
50
100
150
200
250
S2[m]
5
49.5
This illustration shows that the trawl doors are presently situated
at 167 meters below the surface, and they are ascending with 5
meters per minute. The distance between the two trawl doors
is 49.5 meter, and this distance is increasing with 5 meters per
second.
Depth marker line
1 Identify the sensor you wish to use, and make sure that
the sensor is connected to the PI system with correct
communication channels and update rates.
2 Ensure that you have a graphical presentation active on your
PI system.
3 Press the
ADJ button to open the Graphic setup menu.
4 Press the
GAIN+ button repeatedly to reach the Marker line
dialogue.
5 Observe the list of sensors that appear. Only those sensors
that can provide a marker line are listed.
6 Set
Auto to On.
• This allows the PI unit to use the Trawl Calculator to
estimate the correct time delay. (This is not applicable
for purse seiners.)
• If you wish to calculate the delay yourself, set
Auto to
Off. You must then enter the calculated value into the
Delay column.
7 Enter requested value for
Width.
20 316870/A