Instruction manual

Simrad PI Remote/Depth
Note
In order to set up the PI system you must know what kind of
sensors you have, which communication channels they use, and
how often they communicate (the update rate). You need this
information b
efore you start the conguration.
Do not carry out sensor conguration unless absolutely
necessary.
Figure 6 PI Remote/Depth conguration example
Sensor 1:
Demo mode:
Measure 1:
- Update:
- Update:
SINGLE
SINGLE
NONE
NONE
NONE
NONE
- Channel:
- Channel:
SPREAD
DEPTH 300M
FAST
OFF
02
Sensor 2:
Measure 2:
FAST
11
Sensor 3:
Sensor 4:
Sensor 5:
Sensor 6:
Sensor setup
Accept ENT
MENU Exit
GAIN- GAIN+
(CD012105D01)
This example shows how the PI44 (or PI54) is set up to
receive information from a standard PI Spread sensor and a PI
Remote/Depth sensor. Standard communication channels and
update rates are used.
To access the
Sensor Setup menu:
1 Press the
MENU button to open the main menu.
2 On the
Setup menu, select Sensor setup.
3 Press the
ENT button to allow for changes, and then the
same button one more time to accept the warning.
To set up the depth readings from the PI Remote/Depth sensor:
1 Choose an available sensor; 1 to 6.
2 Dene the sensor type (by default None)toSingle.
3 Set
Update to the correct update rate.
4 Set
Measure x1 to the chosen sensor type Depth 300M,
Depth 600M or Depth 1000M depending on the depth rating
on your PI Remote/Depth sensor.
5 Set the communication
Channel to its correct value.
6 Press the
ENT button to save the changes and exit.