Installation manual

28 | Wiring the radar system
4.6 Connect the power cable
A power cable is NOT supplied with the radar processor. A fuse / circuit breaker must be used
on the power cable supplying the radar processor.
Check the system specifications section for the recommended DC input voltage.
The power cable and fuse/circuit breaker requirements are shown in the table.
Scanner
Fuse/Circuit
breaker rating
Maximum length of power
cable
Power cable size
2 kW 12 V DC ONLY 5 A 10 m (33 ft) 14 AWG
4 kW 12-24 V DC 10 A 8 m (26 ft) 14 AWG
Typically the fuse/circuit breaker would be located in a fuse/circuit breaker box with the
fuses/circuit breakers for other devices.
The radar processor must have its own exclusive fuse/circuit breaker. The fuse/circuit breaker
should be labeled appropriately.
To connect the power cable to the radar processor, you must:
Strip away approximately 0.4" (10 mm) of the shielding at the end of the power cable,
and then identify the positive wire and the negative wire
Unscrew the small holding screw from the positive power cable input connector (identified
by the + sign) on the radar processor
Insert the bare end of the positive wire into the positive power cable input connector to
make a connection
Tighten the small holding screw to hold the positive wire in place. Gently pull on the
positive wire to ensure that it is secured
Repeat this process to connect the negative wire to the negative power cable input
connector (identified by the – sign)
Note 2 kW system is for 12 V DC only.