Installation manual

Table Of Contents
Parameters
Beam
Dialogdescription
ThisparameterdialogopenswhenyouclicktheBeambutton
intheHorizontalmenu.
Thisfunctionenablesyoutoselecttheverticalbeamwidthin
thehorizontalpresentation.Thebeamselectioncanbemade
manually,orcontrolledautomaticallybytheselectedrange.
Thewidebeamisdesignedtobeusedwithshorterrangesin
ordertoobtainalargerverticalcoverage.Thismakesthe
sonarless“tiltdependent”inthecatchingphase.
Thenormalbeamisdesignedtobeusedforthemedium
ranges.
Thenarrowbeamisprovidedforthelongerranges.The
focusednarrowbeamhasthehighestsourcelevel,which
increasesthedetectionrange.
Inautomaticmode,thebeamwillchangeautomaticallyasdened
bytherangeselectionsmadebytheWideandNormalbuttons.
Figure33Beamwidths:Wide(A),Normal(B)andNarrow(C)
Beamdialogoptions
Wide:Clickthisbuttontoselecttheupperrangeforthe
widebeamwidthinAutomode.Forrangeshigherthanthis
selection,thebeamwillautomaticallyswitchtoNormalor
NarrowdependingonthecurrentselectionfortheNormal
button.
Normal:Clickthisbuttontoselecttheupperrangeforthe
normalbeamwidthinAutomode.Forrangeshigherthan
thisselection,thebeamwillautomaticallyswitchtoNarrow,
whichisindicatedbyagreyandunavailableNarrowbutton.
Close:Clicktoclosetheparameterdialog.
Help:Clicktoaccesstheon-linehelp.