Installation manual

Operationalprocedures
Howtosetupdepthandheightsensorstomeasuretotal
waterdepth
Ifyouhavebothadepthsensorandaheightsensormountedonthegear,youcanmake
thePI50calculatethetotaldepth.Thesystemwillthenreadeachofthetwosensor
values,addonetotheother,andshowyouthesum.
ThecongurationofthewaterdepthmeasurementismadeintheSelectSensorsdialog
duringthecongurationofaPIDepthsensor.
Note
Youmusthavebothsensorsonyougear .Theymustbephysicallylocatednexttoeach
othertomakethetotaldepthvaluecorrect.
1SetupthePIHeightsensorasdescribedinthededicatedprocedure.
HowtosetupthePIHeightsensoronpage79
2SetupthePIDepthsensorasdescribedinthededicatedprocedure.
HowtosetupthePIDepthsensoronpage78
3Forthededicateddepthsensor,clickAdvancedSensorConguration.
Theavailableheightsensorswillautomaticallybelisted.
4ClickOKtosavethecurrentsettingsandclosethedialog.
5ObservethatthetotaldepthisshowninthePIDepthtrendview.
PIDepthtrendviewonpage60
Howtosetuptheheightsensortoshowthetrawlopening
ThePIHeightsensormaybesetuptodisplaythetrawlopeninginthetrendview.
ThecongurationofthisfunctionismadeintheSelectSensorsdialogduringthe
congurationofaPIHeightsensor.
1SetupthePIHeightsensorasdescribedinthededicatedprocedure.
HowtosetupthePIHeightsensoronpage79
2ClickAdvancedSensorConguration.
3Entertheheightofthetrawldoor.
4ClickOKtosavethecurrentsettingsandclosethedialog.
5ObservethattheheightofthetrawlopeningisshowninthePIHeighttrendview.
PIHeighttrendviewonpage60
328457/A
97