Installation manual
Operationalprocedures
Theoffsetforthespreadsensormustbeenteredmanuallybasedonyour
knowledgeaboutthesensorinstallationandthepropertiesofthegear.Youcan
enteravaluebetween+99and–99meters.
Note
ItisveryimportantthattheChannelnumberandUpdateRateparametersdened
foreachsensorintheSelectSensorsdialogmatchesthecorrespondingparameters
programmedintothesensor .Ifthesevitalparametersdonotmatch,youwillnot
receiveinformationfromthesensor.
9ClicktheAdvancedSensorCongurationbutton,andobservethatadditionalchoices
areaddedtotheSensorCongurationeld.
10ConnecttheSpread/DepthsensorwithstarboardDepthsensor.
Thiswillallowyoutosetupthesystemtomeasureverticalgeometry.Referto
thededicatedprocedure.
→Howtosetupspreadanddepthsensorstomeasureverticalgeometryonpage95
11Ifthisistheonlysensoryouwishtosetup,orthelastsensor,clickOktosavethe
settingsandclosethedialog.
Relatedtopics
•PISpread/Depthsensorviewonpage45
•PISpread/Depthtrendviewonpage62
•HowtosetupthePISpread/Depthsensoronpage87
HowtosetupthePITwinSpreadsensor
ThisprocedureexplainshowtosetupthePITwinSpreadsensorforuse.
Note
Thisisa“dual”sensor .ItwillseizetwocommunicationchannelsonthePI50.
1ClicktheSetupiconundertheMainmenutoopentheSetupmenu.
→Setupmenuonpage112
2ClicktheSelectSensorsbuttontoopentheSelectSensorsdialog.
3ObservetheAvailableSensorseldontheupperleftsideofthedialog.Itlistsall
thesensortypessupportedbythePI50.
4ClickonceontheTwinSpreadsensorinthelist,thenclickthe[►]buttontocopy
thesensortotheSelectedSensorslist.
328457/A
89