Installation manual
Operationalprocedures
7Clickoneofthe[▲]or[▼]buttonstomovethesensorupordownonthelistin
theSelectedSensorseld.
Theorderinthislistalsocontrolstheorderinwhichthesensorsarepresentedinthe
SensorCongurationeld,aswellastheverticalorderofthesensorviewrectangles
inthePI50displaypresentation.
→Howtocontroltheorderofthesensorviewsonpage71
8IntheSensorCongurationeld,choose:
aLabelID
bLabelName
cUpdateRateforeachofthetwosensors
dSensorValueNameforeachofthetwosensors
eThesenamesyouenterareshownintheSensorviews.
→PIHeight/Depthsensorviewonpage54
fChannelNumber
gOffsetforthedepthsensor
Theoffsetforthesensoriscalculatedautomaticallybymeansofthecalibration
procedure.Ifyoualreadyknowtheoffsetvalue,youcanenteritdirectly.
→Howtocalibratethedepthsensorsonpage92
Note
ItisveryimportantthattheChannelnumberandUpdateRateparametersdened
foreachsensorintheSelectSensorsdialogmatchesthecorrespondingparameters
programmedintothesensor .Ifthesevitalparametersdonotmatch,youwillnot
receiveinformationfromthesensor.
9Ifthisistheonlysensoryouwishtosetup,orthelastsensor,clickOktosavethe
settingsandclosethedialog.
Relatedtopics
•PIHeight/Depthsensorviewonpage54
•PIHeight/Depthtrendviewonpage63
•HowtosetupthePIHeight/Depthsensoronpage86
HowtosetupthePISpread/Depthsensor
ThisprocedureexplainshowtosetupthePISpread/Depthsensorforuse.
Threesensorversionsareavailable.Thesearesetupformaximumdepth300m,600
mor1000m.Thedepthrangeisxedbythefactory,andcannotbechangedinthePI
Conguratorutility.
TwoSpreadversionsareavailable.Thesearesetupforstandardorextended(XT)spread
range.ThiscongurationcanbechangedinthePIConguratorutility.