Installation manual
Operationalprocedures
→PITemperaturesensorviewonpage47
eChannelNumber
Note
ItisveryimportantthattheChannelnumberandUpdateRateparametersdened
foreachsensorintheSelectSensorsdialogmatchesthecorrespondingparameters
programmedintothesensor .Ifthesevitalparametersdonotmatch,youwillnot
receiveinformationfromthesensor.
9Ifthisistheonlysensoryouwishtosetup,orthelastsensor,clickOktosavethe
settingsandclosethedialog.
HowtosetupthePITemperature/Depthsensor
ThisprocedureexplainshowtosetupthePITemperature/Depthsensorforuse.
Note
Thisisa“dual”sensor .ItwillseizetwocommunicationchannelsonthePI50.
1ClicktheSetupiconundertheMainmenutoopentheSetupmenu.
→Setupmenuonpage112
2ClicktheSelectSensorsbuttontoopentheSelectSensorsdialog.
3ObservetheAvailableSensorseldontheupperleftsideofthedialog.Itlistsall
thesensortypessupportedbythePI50.
4ClickonceontheTemperature/Depthsensorinthelist,thenclickthe[►]buttonto
copythesensortotheSelectedSensorslist.
Threesensorversionsareavailable.Thesearesetupformaximumdepth300m,
600mor1000m.Thedepthrangeisxedbythefactory,andcannotbechanged
inthePIConguratorutility.
5Observethatanerrormessageappearsifyoutrytoaddtoomanysensorstothe
SelectedSensorseld.
ThePI50canhandlemaximumsixsensors.Rememberthatdualsensorseachseize
twocommunicationchannels.
6IntheSelectedSensorseld,clickonceonasensortoselectit.