Installation manual

Operationalprocedures
4ClickonceontheSpreadsensorinthelist,thenclickthe[]buttontocopythe
sensortotheSelectedSensorslist.
TwoSpreadversionsareavailable.Thesearesetupforstandardorextended(XT)
spreadrange.ThiscongurationcanbechangedinthePIConguratorutility.
5Observethatanerrormessageappearsifyoutrytoaddtoomanysensorstothe
SelectedSensorseld.
ThePI50canhandlemaximumsixsensors.Rememberthatdualsensorseachseize
twocommunicationchannels.
6IntheSelectedSensorseld,clickonceonasensortoselectit.
7Clickoneofthe[]or[]buttonstomovethesensorupordownonthelistin
theSelectedSensorseld.
Theorderinthislistalsocontrolstheorderinwhichthesensorsarepresentedinthe
SensorCongurationeld,aswellastheverticalorderofthesensorviewrectangles
inthePI50displaypresentation.
Howtocontroltheorderofthesensorviewsonpage71
8IntheSensorCongurationeld,choose:
aLabelID
bLabelName
cUpdateRate
dSensorV alueName
ThenameyouenterhereisshownintheSensorview.
PISpreadsensorviewonpage43
eChannelNumber
fOffsetforthespreadsensor
Theoffsetforthespreadsensormustbeenteredmanuallybasedonyour
knowledgeaboutthesensorinstallationandthepropertiesofthegear.Youcan
enteravaluebetween+99and–99meters.
Note
ItisveryimportantthattheChannelnumberandUpdateRateparametersdened
foreachsensorintheSelectSensorsdialogmatchesthecorrespondingparameters
programmedintothesensor .Ifthesevitalparametersdonotmatch,youwillnot
receiveinformationfromthesensor.
9ClicktheAdvancedSensorCongurationbutton,andobservethatadditionalchoices
areaddedtotheSensorCongurationeld.
10ConnecttheSpreadsensorwithportand/orstarboardDepthsensor.
Thiswillallowyoutosetupthesystemtomeasureverticalgeometry.Referto
thededicatedprocedure.
Howtosetupspreadanddepthsensorstomeasureverticalgeometryon
page95