Installation manual

SimradPI50
3ObservetheAvailableSensorseldontheupperleftsideofthedialog.Itlistsall
thesensortypessupportedbythePI50.
4ClickonceontheBottomContactsensorinthelist,thenclickthe[]buttonto
copythesensortotheSelectedSensorslist.
5Observethatanerrormessageappearsifyoutrytoaddtoomanysensorstothe
SelectedSensorseld.
ThePI50canhandlemaximumsixsensors.Rememberthatdualsensorseachseize
twocommunicationchannels.
6IntheSelectedSensorseld,clickonceonasensortoselectit.
7Clickoneofthe[]or[]buttonstomovethesensorupordownonthelistin
theSelectedSensorseld.
Theorderinthislistalsocontrolstheorderinwhichthesensorsarepresentedinthe
SensorCongurationeld,aswellastheverticalorderofthesensorviewrectangles
inthePI50displaypresentation.
Howtocontroltheorderofthesensorviewsonpage71
8IntheSensorCongurationeld,choose:
aLabelID
bLabelName
cUpdateRate
dSensorV alueName
ThenameyouenterhereisshownintheSensorview.
PIBottomContactsensorviewonpage37
eChannelNumber
Note
ItisveryimportantthattheChannelnumberandUpdateRateparametersdened
foreachsensorintheSelectSensorsdialogmatchesthecorrespondingparameters
programmedintothesensor .Ifthesevitalparametersdonotmatch,youwillnot
receiveinformationfromthesensor.
9Ifthisistheonlysensoryouwishtosetup,orthelastsensor,clickOktosavethe
settingsandclosethedialog.
HowtosetupthePICatchsensor
ThisprocedureexplainshowtosetupthePICatchsensorforuse.
Note
ThisprocedureisalsousedtosetupthePIRipsensor .
76
328457/A