Installation manual

Operationalprocedures
EChooseChannelNumber.
aChannelNumber
ThisisthecommunicationchannelusedbetweenthesensorandthePI50
system.
Note
TheChannelNumberparameterisvital.Thecommunicationchannel
numberyouchooseherem
u s t complytothechannelnumberprogrammed
intothesensor.Ifthesedonotmatch,thecommunicationwillnotwork.By
default,thechannelnumberwillmatchthefactorysetting.
Ifyouusemorethanonesensorsofthesametypeatthesametime,the
channelnumberofoneofthesensorsmustbechangedtomakeitunique
forthesensor.Thismustbechangedb
o t h intheactualsensor,a n d inthe
SelectSensorsdialogduringconguration.
Thedefaultcommunicationchannelsforthevarioussensorsarelistedin
chapterPI50Sensors.
Tochangethechannelnumberonthesensor,usethePIConguratorutility.
FObservetheOffsetvalue.
aOffset
Sensorsmeasuringspreadanddepthcanhaveanoffsetvalue.
Theoffsetvalueforthedepthsensorsaredeterminedduringcalibration.
Howtocalibratethedepthsensorsonpage24
Theoffsetvalueforthespreadsensormustbeenteredmanuallybased
onyourknowledgeaboutthephysicallocationsofthesensorsandthe
propertiesofthegear.
13ClickApplytosavethesensorconguration.
14CheckthatallsensorsareshowninthePI50presentation.
15ClickOKtosavethecurrentsettingsandclosethedialog.
HowtosetupthePIBottomContactsensor
ThisprocedureexplainshowtosetupthePIBottomContactsensorforuse.
1ClicktheSetupiconundertheMainmenutoopentheSetupmenu.
Setupmenuonpage112
2ClicktheSelectSensorsbuttontoopentheSelectSensorsdialog.
328457/A
75