Installation manual
Displayviews
PIGeometrytrendview
Figure37PIGeometrytrendview
ThePIGeometryprovidestwotrendviews
thatcanbeopenedindividually.Theshows
thedistancebetweenthecentreofthetrawl
andthetwotrawldoors.
Thetopgraphprovidesanoveralldescription
ofthegeometry.Thebottomgraphpresents
amoredetailedviewofthetwodistances
thataremeasuredbythesensor.
ATheverticalscaleisdenedbythe
settingsmadewiththeRangeandStart
RangebuttonsontheMainmenu.
BThehorizontalscaleisdenedbythe
parameterselectedintheTrendHistory
LengthbuttonontheDisplaymenu.
Thetimecanbeselectedfrom5to1440
minutes(24hours).
CThehistorycurvesusethesametwocoloursthatareusedtoidentifythestarboard
andportmeasurement.Thelabelsattherightendofthecurveidentifythesensor’s
LabelIDandthetypeofsensor.
PIHeight/Depthtrendview
ThePIHeight/Depthprovidestwoseparatetrendviews,oneforheightandonefor
depth.Forinformation,see:
→PIHeighttrendviewonpage60
→PIDepthtrendviewonpage60
Relatedtopics
•PIHeight/Depthsensorviewonpage54
•PIHeight/Depthtrendviewonpage63
•HowtosetupthePIHeight/Depthsensoronpage86
PISeineSoundertrendview
ThePISeineSounderprovidestwoseparatetrendviews,oneforheightandonefor
depth.Forinformation,see:
→PIHeighttrendviewonpage60
→PIDepthtrendviewonpage60
328457/A
63