Installation manual

Displayviews
Note
Thisisa“dual”sensor .ItwillseizetwocommunicationchannelsonthePI50.
Figure23PITemperature/Depthsensorview
ASensoridentier:TheidentieristheLabelIDparameter,thesensornameis
theSensorValueNameparameter.YoucancontroltheseparametersintheSelect
Sensorsdialog.
ThecolourcodeisissuedautomaticallybythePI50system.Thesamecolouris
usedintheTrendviewandintheHistoryeld.
BCurrentdepth:Thisthecurrentdepthmeasuredbythesensor.Thecurrent
measurementunitisshown,aswellasabluearrowhead.Thearrowheadindicates
thecurrentverticalmovementofthesensor;upordown.Inthisexamplethesensor
measures82,5metersfromtheseasurfaceanddowntothesensor,andthesensor
andthusthegearisslowlyrisingwith3meterseachminute.
CDepthchanges:Thisdigitshowsdepthchangesrecordedbythesensor,andthusthe
ascendingordescendingspeedofthenet.Thevalueisshowninunitsperminute.
Thedirectionisshownwiththebluearrowhead.Ifthesensordoesnotdetectany
depthchanges,thearrowheadisremoved.
DHistoryeld:Whenthesizeofthepresentationrectanglepermits,ahistoryeld
isshown.Theeldoffersagraphicalpresentationofthesensorinformationfor
thelast20minutes.Theverticalrangeissetautomaticallydenedbythecurrent
measurements.
EPulselampandTrendviewicons:ThegreenPulselampiconasheseverytimea
signalisreceivedfromthesensor.ClicktheTrendviewicontoopen(andclose)
theTrendviewforthesensor.
FCurrenttemperature:Thisthecurrenttemperaturemeasuredbythesensor.The
currentmeasurementunitisshown,aswellasabluetriangle.Thetriangleindicates
ifthetemperatureisincreasingordecreasing.Inthisexamplethetemperatureis
measuredto4,5°C,anditisrapidlyincreasingwith2°Ceachminute.
328457/A
49