Installation manual
Operationalprocedures
Eachsensorhasanindividualalarmsetting.Toenableanalarm,youmustdene
minimumandmaximumlimitswithinthesensor’srange,andclicktoenablemessage
and/oraudionotication.
[5]
Ifthealarmistriggered,anaudiblesignalmaythusbeprovided,and/oryouwillreceive
amessageindicatingwhichsensorthatcausedthealarm.
Onceanalarmhasbeentriggered,itisautomaticallydisabledafter20seconds.After
thistimeitmaybetriggeredagainunlessthealarmsituationhasbeenrectied,oryou
havedisabledthealarm.
TheBottomContactandCatchsensorscanonlyprovidealarmswhentheyareactivated.
Thealarmsettingsyouspecifyareautomaticallysavedforthecurrentsession.Ifyou
alsowishtokeepthemforfutureuse–withthesensorcongurationyouhavespecied
–clicktheUserSettingbuttontosave.
1ClicktheSetupiconundertheMainmenutoopentheSetupmenu.
→Setupmenuonpage112
2ClickAlarmLimitstoopentheAlarmLimitsdialog.
ObservethattheAlarmLimitsdialogisdynamic.Itliststhesensorsyouhave
currentlyselectedintheSelectSensorsdialog,andplacedthemintheorderyou
havedened.TheLabelIDandSensorValueNameprovidedarethesameasthose
youselectedintheSelectSensorsdialog.
3Foreachsensor:
aSetupthemaximumandminimumalarmlimitsinthespinboxes.
bClicktoenablemessageand/oraudionotication
4Todisableallalarms,removeallMessageandAudioselections.
5ClickOKtosavethecurrentsettingsandclosethedialog.
Howtoaccessthelogles
ThisproceduredescribeshowtoaccesstheloglesonthePI50.
WheneverthePI50issuesamessage,itisshownintheMessagesdialog.Simultaneously,
themessagesarestoredinanumberoflogginglesontheharddisk.Ifyouexperience
abnormalbehaviour,andwishtoconsultyourdealerand/orSimrad,theseloggingles
areveryuseful.Thefollowingprocedureexplainshowtoaccesstheseles.
5.Inordertohearanaudiblealarm,youmusteitherplacethePI50computerinapositionwherethe
internalloudspeakercanbeheard,oryoumustinstallaseparateloudspeakersystem.
328457/A
101