Installation manual
70 | Commission the system
Transducer type (Echosounder)
Transducer type is used for selecting the transducer model connected to the echo
sounder module. In some transducers with built-in temperature sensors, the
temperature may not be correct if the correct transducer is not selected from the
transducer type menu. Note: Transducers with a 6 pin connector
See compatible transducer list on page 86
Note: SimNet depth sources will have their own calibration please see page 59
Radar setup
Before starting the system for the first time, check the following;
• Check radar is physically clear to rotate
• Leave a HD pulse radar in standby for 30 minutes before transmitting for the first
time
• Check all personnel are clear of radar beam (HD Radar)
• Check all wiring is correctly connected. Apply power to the breaker
Basic set up is required on all new radar installations. The set up varies slightly between
Boradband radar and the range of conventional HD pulse radars. The NSO will detect the
type of radar and display relevant information.
Broadband Radar™ HD Pulse Radar
To commission a
BR24 Radar:
• set bearing
alignment
• set antenna
height
• local interference
rejection (if
needed)
To commission a
pulse radar;
• set bearing
alignment
• set antenna
height.
• set range offset
• Park angle for
open array
scanners
HD Pulse Radars: Leave in standby for 30 min before transmitting. (fi rst time only) to
burn in the magnetron.
Radar software version
Radar type and software version are displayed under radar installation. To upgrade radar
software refer to Software Upgrades on page 78.