Installation manual

Commission the system | 49
Turning on for the rst time
From the factory the OP40 controller is not assigned to control any NSO processors and
will not be responsive until it as been assigned to control an NSO or NSE processor.
A press and hold of the DISPLAY key for 5 seconds from any OP40 will start all NSO
processors and display the OP40 Configuration Wizard on the screen
Turn on all NSO processors System starts and enters OP40 con gura-
tion wizard
(Active display)
MOB
DISPLAY
5 Sec
All NSO will start and enter into the OP40 Con guration mode. Note: NSE displays will
need to be turned on using their PWR button (if not already switched on by the yellow
power control wire)
When in OP40 con guration mode, all four OP40 LEDs will be lit red
Note: OP40 con guration wizard can be entered into at any time with a 5 second press
of the DISPLAY key.
Assigning an OP40 control of a single display
Press 1, 2, 3 or 4 to assign DISPLAY A to
LED position 1, 2, 3 or 4 respectively.
Example user presses 1
DISPLAY A is now assigned to LED position
1 of this OP40
STBY
AUTO
PWR
1
3
6
7
PQRS
8
TUV
9
WXYZ
MNO
5
JKL
2
ABC DEF
GHI
4
0
STBY
AUTO
Assigning an OP40 to control multiple displays
Press DISPLAY key until the display to be
assigned shows the active display page.
Displays connected to other NSO proces-
sors will show the inactive selection page
It is logical to assign LED(s) 1 through 4 (left to right) to displays moving from left to
right.
Note: that during assignment the letters assigned to each display (for assignment pur-
poses only) are random and are not in any particular order.
Assign each display to an LED number by selecting a number one through four