Installation manual
32 | Wiring the NSO
The drawing below shows a small SimNet network. Power is introduced at one end using
a SimNet power cable with termination ending with a second terminator.
12 V DC
ABC D E
H
F
I
G
T T
T
SimNet drop cable
SimNet power
SimNet terminator
-
+
G
Key Description
A SimNet power source. Stable 12 V DC only
B 5 Amp fuse or breaker
CSwitch
D SimNet power cable with termination (red disc) (24005902)
E SimNet 7 way joiner
F NSO Marine Processor
G Micro-C to SimNet cable
HOP40 Controller
IGS15