Installation manual

24 |
Speci cations |10kW and 25kW Installation Manual
TXL-25S-7
Type of emission PON - Passed FCC/IC/R&TTE Type Certi cation:
FCC ID: CKENKE2254
IC ID: 768C-NKE2254
R&TTE: Tele cation CE0560
Ambient conditions According to IEC60945-4
Operating Temperature: -25 to +55°C
Relative humidity: +40°C, 93% RH
Vibration:
Amplitude 2 to 13.2Hz, +/-1mm +/- 10%
Amplitude 13.2 to 100Hz,
Gravity acceleration 7m/sec2
Waterproof:IPX6
Relative wind velocity 51.5 m/sec (100 Knots)
Power consumption 240W (Max.) in maximum wind velocity
DC input 21.6 to 31.2 V (DC 24 Volt Systems)
Pre-heating time Minimum 180 sec
Outside dimensions Height 536mm x Swing Circle Diameter 2270mm
Mass 58kg+/-10%
Plane of polarization Horizontal Polarization
Beam width Horizontal 1.0°+/-10% (-3dB width)
Vertical 20° +20% (-3dB width)
Side lobe level Below -26dB max. (within ±10°)
Below -30dB max. (outside ±10°)
Rotation 24 rpm (Min 20rpm at Max 100Knots)
Transmitter frequency 9410±30MHz
Peak power output 25kW±50% under any pulse condition
Transmitter tube Magnetron NJRC Model M1568BS
Pulse length/Pulse Repetition
Frequency
0.07µS+/-30%/2250Hz +/-5%
0.20µS+/-25%/2250Hz +/-5%
0.30µS+/-25%/1900Hz+/-5%
0.40µS+/-25%/1400Hz+/-5%
0.80µS+/-25%/750Hz+/-5%
1.0µS+/-25%/650Hz+/-5%
1.2µS+/-25%/510Hz+/-5%
Duplexer Circulator NJC3901M and Diode Limiter NJS6930
Mixer MIC front-end NRG-162
IF ampli er Center frequency: 60MHz +/-3MHz
Bandwidth:
25MHz +/-3MHz (0.07µS)
8MHz +/ -2MHz(0.2µS, 0.3µS, 0.4µS)
3MHz +/-1MHz (0.8µS, 1.0µS, 1.2µS)
Gain: 90dB min.
Characteristic: Log
Output: -2V for 100dB Typical
Bandwidth controlled by serial port
Noise  gure 7.5dB (Average)
Com Port RS485 9600bps Half Duplex
Propriety Digital COM Speci cation
Standard scanner cable length 20m (packed in carton)
Maximum allowable scanner cable
length
30m