Instruction manual
Configuration and Setup
20221586F 133
Instance number
An item to identify units by a
number when the autopilot is
connected to a NMEA2000
Network. On SimNet units the
Instance number is added to the
product name e.g. AP26-1, AP26-
2 for easy identification on
various display screens.
SimNet gateway
Indicates which control unit that
transmits and receives information
on SimNet. The display verifies
by reading ‘Yes’, all other units
read ‘No’.
Global SimNet reset
Resets the entire SimNet setup in
the Simrad Group and initiates a
new automatic interface setup.
See chapter
4.1.
Master Reset
Note ! A Master Reset is part of the final test at the factory, which will
reset the memories to factory settings. Unless you need to clear
all stored values during the installation setup procedure, you
should not perform a Master Reset.
Under Service in the Installation
Menu, select Master reset of
memories by pressing the STBD
button and confirm this by
rotating the course knob
clockwise.
The Master Reset needs a double
confirmation to prevent an
accidental reset. To perform a
Master Reset, rotate the course
knob clockwise and observe the
display; then rotate the course
knob counter clockwise. The