Installation manual

Interfaces and integration
Wiring procedure
1 Locate the RS-232 serial port that can be used to connect
the sonar system.
2 On the ES60 computer, connect the transmit signal
Tx on
pin 3, and
ground on pin 5.
3 On the Sonar Interface Unit, use one of the serial line
connectors
TB1 through TB7. Connect the receive signal
Rx on pin 1, and ground on pin 5.
4 Ensure that the length of the cable does not exceed
approximately 50 meters. If a longer cable is required, you
may need to use buffer ampliers on the serial li ne.
Setup procedure
1 On the ES60, access the Install menu, and
2 If you wish to use the same serial line as the Navigation
input, open the
Navigation Interface dialogue box.
3 If you wish to use the same serial line as the Heave input,
open the
Heave Sensor dialogue box.
4 If you wish to use the same serial line as the Trawl input,
open the
Tr awl Interface dialogue box.
5 Click the
Depth output button to open the Depth Output
dialogue.
6 Click
Depth Output to enable the output.
7 Click
Channel to select which transceiver and frequency
you wish to retrieve and export the depth information from.
In most cases, the lowest frequency is used.
8 Click
Telegram to choose which format to use on the output
communication.
The $SDDBS telegram contains the depth below the
surface.
The $SDDBT telegram contains the depth below the
transducer.
The $SDDPT telegram contains the depth below the
transducer and the distance between the transducer and
the water line.
The Simrad telegram outputs information compatible
for EA500 and EK500 echo sounders.
The Atlas telegram outputs information compatible for
Atlas echo sounders.
9 Choose the telegram you wish to use.
Related topics
Generic RS-232 Serial line cable on page 47