Installation manual
Interfaces and integration
Wiring procedure
1 Locate the RS-232 serial port that can be used to connect
the sonar system.
2 On the ES60 computer, connect the transmit signal
Tx on
pin 3, and
ground on pin 5.
3 On the Sonar Interface Unit, use one of the serial line
connectors
TB1 through TB7. Connect the receive signal
Rx on pin 1, and ground on pin 5.
4 Ensure that the length of the cable does not exceed
approximately 50 meters. If a longer cable is required, you
may need to use buffer amplifiers on the serial li ne.
Setup procedure
1 On the ES60, access the Install menu, and
2 If you wish to use the same serial line as the Navigation
input, open the
Navigation Interface dialogue box.
3 If you wish to use the same serial line as the Heave input,
open the
Heave Sensor dialogue box.
4 If you wish to use the same serial line as the Trawl input,
open the
Tr awl Interface dialogue box.
5 Click the
Depth output button to open the Depth Output
dialogue.
6 Click
Depth Output to enable the output.
7 Click
Channel to select which transceiver and frequency
you wish to retrieve and export the depth information from.
• In most cases, the lowest frequency is used.
8 Click
Telegram to choose which format to use on the output
communication.
• The $SDDBS telegram contains the depth below the
surface.
• The $SDDBT telegram contains the depth below the
transducer.
• The $SDDPT telegram contains the depth below the
transducer and the distance between the transducer and
the water line.
• The Simrad telegram outputs information compatible
for EA500 and EK500 echo sounders.
• The Atlas telegram outputs information compatible for
Atlas echo sounders.
9 Choose the telegram you wish to use.
Related topics
Generic RS-232 Serial line cable on page 47
304699/A 93