Installation manual

Interfaces and integration
BI500
General Purpose Transceiver
BI500 interface
The ES60 can communicate with an external devices that can
benet from the processed data. Such devices include the Olex
chart plotter system. This communication is controlled by the
BI500 dialogue box.
The following telegrams may be exported:
Parameter
Echogram
Echo trace
Navigation
Vessel log
The interface will require the absolute identity of the remote
UDP port and the remote IP address.
Wiring procedure
1 Locate the Ethernet port you wish to use.
2 If no Ethernet port is available, an Ethernet switch m ay be
inserted between the computer and the transceiver.
3 If you connect an Ethernet cable directly between the ES60
computer and a remote computer, you must use a Ethernet
cable. If you connect the other computer by means of an
Ethernet switch, you must use “straight” Ethernet cables.
Setup procedure
1 On the ES60, access the Install menu, and open the BI500
dialogue box.
2 Click to select which datagrams you wish to export, and set
up the other parameters to suit your special requirements.
3 Dene the
Remote UDP Port.
4 Dene the
Remote IP Address for the computer you wish
to export the information to.
Related topics
Ethernet cable with RJ45, “straight” on page 52
Ethernet cable with RJ45, “crossover” on page 53
Transceiver interface
The ES60 computer communicates with the General Purpose
Transceiver using one or more Ethernet cables. The number and
type of cables required depends on the system conguration.
304699/A 85