Installation manual
Cable layout
Split beam transducer
This is the termination of the transducer cable from a single
frequency, split beam transducer to the transducer socket on the
General Purpose Transceiver Unit (GPT). The other end of the
cable is permanently fixed to the transducer.
M
E
F
J
H
D
C
K
L
A
B
N
Transducer
cable
E
H
D
C
F
J
A
B
Junction Box (1:1)
(Optional)
GPT Transducer
socket
Channel 1
Channel 2
Channel 3
Channel 4
Connect to plug housing
W802-4
Rev.E
Single frequency, split beam termination
Forward
Starboard
Port
Sections seen from top
of the transducer
2
1
3
4
21
3
4
White
Blue
White
Blue
Blue
Orange
Green
Brown
White
White
White
White
White
Blue
White
Blue
Black
Black
Black
Black
Black
Black
Black
Black
Screen
Alternative cable
colours
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the transducer cable in a steel conduit.
Related topics
Cable splicing on page 140
Steel conduit on page 140
GPT Transducer plug connection on page 105
304699/A 71