Installation manual
Simrad ES60
Cable between PI30/32 and echo s ounder
This cable is used to provide a two-way communication between
the echo sounder and a PI30 or PI32 catch monitoring system.
W620H
Rev.A
Communication between PI30/32 and echo sounder
1
5
5
3
3
2
2
6
4
Not used
Tx - Ground
Rx - Data in
Rx - Ground
Alarm log
Tx - Data out
Receive (Rx)
Transmit (Tx)
Ground
NMEA connector
on PI system
Suitable serial line
connector on echo
sounder computer
Plug and connector
manufacturer:
www.conxall.com
A small circular marker
identifies pin 1.
(1)
(2)
(3) (6)
(4)
(5)
View:
Looking the
socket on the
rear side of the
cabinet = Wiring
view of
on male and female
plugs.
into
cable side
• Conductors: 9 x 2 x 0.5 mm2
• Screen: Screened twisted pairs and overall braided
• Voltage: 60 V
• Maximum diameter: Limited by the plugs
66