Installation manual
Simrad ES60
GPT Alarm output
This cable is used to connect the General Purpose Transceiver
(GPT) to an external device for audible and/or visual alarms.
The cable connects to the 25–pin D-sub connector on the front
side of the GPT.
20
11
Alarm out
Ground
W620J
Rev.A
Alarm output
The cable screen is connected to the plug house.
GPT
25-pin D-sub connector
25
14
1
13
Auxiliary
connector
(female)
SIMRAD
GPT
Connect the alarm output
to a opto-coupler or a
small relay.
DO NOT attempt to power
lamps or sounders directly!
• Conductors: 2 x 0.22 mm2
• Screen: Overall braided
• Voltage: 60 V
• Maximum diameter: Defi ned by the plugs
62
304699/A