Installation manual

Transducer Installation
Cable gland for steel hulls
This cable gland kit is designed f or steel vessels. It must be
welded to the hull plates.
(CD17008A)
ø35
ø65
A
A
B
C
C
D
E
F
(A) = Steel conduit
(B) = Stufng tube, DNV approved carbo
n s teel st52.3
(C) = Washers
(D) = Rubber gasket
(E) = Packing nipple. Make sure tha
t you do not damage the
transducer cable by tightening
the packing nipple too hard!
(F) = Cable to the echo sounder (o
r a junction box)
The cable gland kit includes a
ll of the necessary parts needed to
install the unit except scre
ws.
Simrad recommends that a one
inch steel conduit (that the
transducer cable will be ru
n through) with an inside threaded
diameter of three-quart
er inches is welded to the gland’s stufng
tube. The conduit must e
xtend to above the vessel’s water line.
304699/A 137