4.2 Class 2 system
No Symptom Possible Cause Suggested solution
1 No data from
SimNet are
displayed.
SimNet cable not
connected
No power on SimNet
No termination plug in the
network
Check installation
Check switch and fuse
for SimNet power
2 Some data from
SimNet are
displayed but
not all
Data source selection may
be locked on wrong or old
source.
Source may be turned off
or not connected correctly
to power or network.
Make a Source
Selection Reset or
master reset.
3 Unstable display
of SimNet data
No termination in the
network
Electrical interference from
other units on boat
Not sufficient power in
endpoints of network.
Insert a termination plug
as described in this
installation manual.
Fit interference
suppressors to
equipment responsible.
Check network DC
voltage in network
endpoints. (9 – 16VDC)
4 Only data on
some of the
products in the
network
Loose or broken cables
Product not connected to
the network / interface
Check cables connected
to the first faulty unit,