4.1 Class 1 system
No Symptom Possible Cause Suggested solution
1 AutoSourceSelec
t does not start
automatically
There is no external
source connected to the
product (SimNet or
NMEA).
Product has already been
setup once.
Check installation and
that all data sources are
powered up.
Make a Source Selection
Reset or a Master reset of
the product.
2 Not all
DataTypes has
automatically got
a data source
appointed.
There is no external data
source supplying the
required DataType
connected to the product
(SimNet or NMEA).
The source may not send
out the DataType on
SimNet or NMEA.
Check that there is a data
source for the DataType.
Check that the data
source is correctly
installed and setup (if
required)
Make a manual setup of
the missing source, or
use Source Select Update
function if available in
the product.