Installation manual

Installation Manual
20222006 / Rev. A 19
Example:
Figure 3-4 Large system
16 products interconnected via 92 meter (306’) network cable
The best place to feed the network power is the point where the
SF (L NL) value in each of the branches is most equal.
However, it will work without problems as long as the SF value
in each branch is below 600.
Determine the total NL values separately for both the left
and right branches.
Add up the cable length separately for each of the two
branches (exclude the 30 meter wind sensor cable).
Calculate the SF (left) and SF (right). Make sure that each
SF is below 600.
If one branch has a too high SF, try to better balance the
network by moving the power cable and T-joiner into the
branch with the higher SF.