For reliable network performance use the following guidelines:
Connect the battery to the network power wires at one
single point to avoid interfering noise loops.
Use good quality and saltwater resistant accessories
(circuit breaker, fuse holder, power cable terminals)
Use at least 2x1.0 mm
2
(16 AWG) cable if you need to
extend the standard SimNet power cable (2m / 6.7’) to
reach the battery, and remember to add the length of this
to the total SimNet cable length (L - page 15) when you
are planning your system.
Using a heavier gauge cable between the battery and the SimNet
power cable will reduce the effect on the total network cable
length (L). (See Figure 3-1 and page 16.)
2 x 3.0 mm
2
(12 AWG) add only 1/5 of the extended cable
length as additional L.
2 x 4.0 mm
2
(10 AWG) add only 1/6 of the extended cable
length as additional L.
2 x 6.0 mm
2
(8 AWG) add only 1/10 of the extended cable
length as additional L.