Installation manual

Interfacesandintegration
bOntheseriallinesocketonthePI50computer,connecttheRS-232cableas
follows:
ReceivesignalRxonpin2.
TransmitsignalTxonpin3.
CommonGroundonpin5.
GenericRS-232Seriallineonpage35
GenericRS-232Seriallineonpage36
cOntheexternalsystem,wireasdescribedintherelevantdocumentation.
dEnsurethatthetotallengthoftheseriallinecabledoesnotexceed
approximately50meters.
Ifalongercableisrequired,youmayneedtousebufferampliersonthe
serialline.
2ClicktheSetupiconundertheMainmenutoopentheSetupmenu.
3ClicktheInstallationbuttontoopentheInstallationsub-menu.
Onthesub-menuI/OSetuptoopentheI/OSetupdialog.
4IntheI/OSetupdialog,selectwhichseriallinetousetoexportthePIinformation.
5Clickonthechosenporttoselectit,thenclicktheOutputbuttontoopentheSelect
Outputsdialog.
6IntheSelectOutputsdialog,locatethePI_NMEAoptionontheleftside,andclick
the[►]buttontoconnectit.
7ClickonceonthePI_NMEAoptionontheleftside,thenclickCongureOutput.
8ObservethatthePIDataOutputdialogopens.
9InthePIDataOutputdialog,clicktoenabletheDatatelegramstobeexported.
10ClickOKtosavethecurrentsettingsandclosethedialog.
11ObservethatyouarebackintheSelectOutputsdialog.
12ClickOKtosavethecurrentsettingsandclosethedialog.
13IntheI/OSetupdialog,clickonthechosenporttoselectit,thenclicktheSetup
buttontoopentheSerialPortSetupdialog.
14IntheSerialPortSetupdialog,entertherelevantparameterstosetuptheport.
StandardNMEA0183communicationparametersonpage105
328459/B
57