Installation manual
SimradPI50
Hydrophonejunctionbox
Thehydrophonecablewillneedtobespliced.D
o n o t splicewithsolderandelectrical
tape,oracommercialterminalblockforhomelightning!Thecableshieldingmust
howevern
o t begroundedinthejunctionbox.
Note
Youmustuseametalbox,andtheboxmustbegrounded.
Asuitablejunctionboxmustbeprovidedbytheinstallationshipyard.
W813A
Rev.B
Hydrophonecable-Junctionbox
0
0
Tohydrophone
Hydrophone
connector
Junctionbox(metal)
Cableshield
Note: ThecableshieldmustNOT be
connectedtoJunctionBoxground!
Cablespecications
•Conductors:6x0.5mm²+Ground
•Screen:Overallbraided
•Voltage:60V
•Maximumdiameter:8mm
50