Installation manual

SimradPI50
Cabletrays
Allpermanentlyinstalledcablesassociatedwiththesystemmustbesupportedand
protectedalongtheirentirelengthsusingconduitsand/orcabletrays.Theonlyexception
tothisruleisoverthenalshortdistance(maximum.0,5meters)asthecablesruninto
thecabinets/unitstowhichtheyareconnected.Theseshortserviceloopsaretoallowthe
cabinetstomoveontheirshockmounts,andtoallowmaintenanceandrepair.
Whereverpossible,cabletraysmustbestraight,accessibleandplacedsoastoavoid
possiblecontaminationbycondensationanddrippingliquids(oil,etc.).Theymustbe
installedawayfromsourcesofheat,andmustbeprotectedagainstphysicaldamage.
Suitableshieldsmustbeprovidedwherecablesareinstalledinthevicinityofheat
sources.
Unlessitisabsolutelyunavoidable,cablesshouldnotbeinstalledacrossthevessel’s
expansionjoints.Ifthesituationisunavoidable,aloopofcablehavingalength
proportionaltothepossibleexpansionofthejointmustbeprovided.Theminimum
internalradiusoftheloopmustbeatleasttwelvetimestheexternaldiameterof
thecable.
Whereaservicerequiresduplicatesupplylines,thecablesmustfollowseparatepaths
throughthevesselwheneverpossible.
Signalcablesmustnotbeinstalledinthesamecabletrayorconduitashigh-power
cables.
Cablescontaininginsulationmaterialswithdifferentmaximum-ratedconductor
temperaturesshouldnotbebunchedtogether(thatis,inacommonclip,gland,conduit
orduct).Whenthisisimpractical,thecablesmustbecarefullyarrangedsuchthatthe
maximumtemperatureexpectedinanycableinthegroupiswithinthespecications
ofthelowest-ratedcable.
Cableswithprotectivecoveringswhichmaydamageothercablesshouldnotbe
groupedwithothercables.
Cableshavingacoppersheathorbraidingmustbeinstalledinsuchawaythat
galvaniccorrosionbycontactwithothermetalsisprevented.
Toallowforfutureexpansionofthesystem,allcablesshouldbeallocatedspare
conductorpairs.Also,spacewithinthevesselshouldbesetasidefortheinstallation
ofextracables.
RadioFrequencyinterference
Allcablesthataretobepermanentlyinstalledwithin9m(30ft)ofanysourceofRadio
Frequency(RF)interferencesuchasatransmitteraerialsystemorradiotransmitters,
must,unlessshieldedbyametaldeckorbulkhead,beadequatelyscreenedbysheathing,
braidingorothersuitablematerial.Insuchasituationexiblecablesshouldbescreened
whereverpossible.
128