User manual
Operationalprocedures
Poweron/offprocedures
TheseproceduresexplainhowtoswitchtheES70systemonandoff.
Note
WhenyoupoweruptheES70fortheveryrsttime,observetheproceduresinchapter
Installationonpage300.
Makesurethatyouhavesufcientwaterbelowthehullbefore
youpoweruptheES70.If
youstarttheES70withthetransducerinair ,youmaydamageitbeyondrepair!
Topics
•PoweringuptheES70onpage45
•PoweringdowntheES70onpage47
PoweringuptheES70
Purpose
ThisprocedureexplainshowtopoweruptheSimradES70.
ThisprocedureassumesthatyouhaveconnectedoneormoretransceivertotheES70.If
thisisnotthecase,observetherelevantstart-upprocedureinchapterInstallation.
→SettinguptheES70transceiver(s)forthersttimeonpage303
Procedure
1Verifythatthetransceiver(s)areswitchedon.
TheGeneralPurposeTransceiver(GPT)isnotprovidedwithanon/offswitch.
Unlessadedicatedsolutionhasbeenprovidedduringtheinstallationtofacilitate
poweron/off,thetransceiver(s)arepermanentlypoweredup.However,iftheES70
hasnotbeenusedforalongerperiodoftime,thepowertothetransceiver(s)may
havebeendisconnected.
2Powerupthecolourdisplay.
Ifrequired,refertotheinstructionsprovidedbythedisplaymanufacturer.
3PoweruptheES70computer.
Waitfortheoperatingsystemtostartup.
4Double-clicktheES70icononthedesktoptostarttheprogram.
5WaitwhiletheES70programstartsonthecomputer.
6Chooseusersettings.
Duringtheprogramload,adialogappearstoletyouchoosefromthecurrentuser
settingsavailableontheES70.
Thedialogisonlyvisibleafewseconds.Youdonotneedtomakeachoicehere.
YoucanselectusersettingatanytimebymeansoftheUserSettingsdialogon
theMainmenu.
338106/C
45