Example3StartRangeinasurfaceechogram
Inasurfaceechogram,settheStartRangevalueto10meters.Thiswillmake
theechogramstartfrom10metersbelowtheseasurface(providedthatthe
transduceroffsethasbeendened).SetRangetothecurrentdepthplus20
meters.Theechogramwillnowshowtheareafrom10metersbelowthesea
surface,anddownto10meters“below”thebottom.Thebottomcontouris
easilydetectedwhenthedepthchanges.
5SetRangetoAuto.
SetStartRangeto0.
Observethechangesmadetothesurfacerelatedechogram.
6Clickinabottomrelatedechogramtomakeit“active”.
7ObservetheRangeandStartRangebuttonsontheMainmenu.
Example4StartRangeandRangeinbottomrelatedechogram
Inabottomechogram,settheStartRangevalueto–5meters.Thiswillmake
theechogramstartfrom5metersabovethebottom.SetRangetothe5meters
plus10=15meters.Theechogramwillnowshowtheareafrom5meters
abovethedepth,anddownto10meters“below”thebottom.Thebottom
contourwillappearasaatline.
8SetRangeto15.
SetStartRangeto5.
Observethechangesmadetothebottomrelatedechogram.
Savingthecurrentusersettings
Thisprocedureexplainshowtosavethecurrentcongurationandparametersettings.
Ifyouhaveseveraluserswithfavouritecongurations,ifyouworkwithdifferentgears,
orwithdifferenthardwarecongurations,depthorbottomconditions,werecommend
thatyousavetheES70operationalparametersforfutureuse.
Procedure
1ObservetheMainmenu.ItisnormallylocatedontherighthandsideoftheES70
presentation.
2OntheMainmenu,clickUserSettingstoopentheUserSettingsdialog.
TheUserSettingsdialogallowsyoutosavethecurrentusersettings(parameter
selections),andtoretrievepreviouslysavedfactoryorusersettings.
UserSettingsonpage156
3IntheUserSettingdialog,clicktheSaveCurrentSettingbutton.
4IntheSettingdialog,clickOKtoacceptthesuggestedname.
338106/C
33