User manual

Operationalprocedures
7OntheEchogramtab:
aSetTVGtoPower(NoTVG)
bSetEchogramTypetoSurface
8ClickOKtosavethecurrentsettingsandclosethedialog.
9ClicktheOperationicon.
ThisiconislocatedundertheMainmenu.ItisusedtoopentheOperaiton
menu.
Operationmenuonpage150
10ClickNormalOperationtoopentheNormalOperationdialog.
ThepurposeoftheNormalOperationdialogistoofferyouanoverviewofthe
currenttransceiverparameters,andtoprovideyouwiththeabilitytochangethem.
NormalOperationonpage169
11IntheNormalOperationdialog,setModetoTest.
12ClickOKtosavethecurrentsettingsandclosethedialog.
13OntheMainmenu:
aSetRangeto100m
bSetGainto130
14Movethecursorovertheechointheechogram,andobservethetooltipinformation.
Foroperationalfrequenciesbelow
120kHz,verifythefollowingresults:
Split-beamGPTwithmorethan1kWoutput:–64dB±1dB
SinglebeamGPTwith1kWoutputorless:–67dB±1dB
Foroperationalfrequenciesabove
120kHz,verifythefollowingresults:
Split-beamGPTwithmorethan1kWoutput:–120dB±1dB
SinglebeamGPTwith1kWoutputorless:–130dB±1dB
15Reversethisproceduretorestorenormaloperation,orselectfactorysettingsin
theUserSettingdialog.
RecyclingGPTpowerrecycle
TheES70computermaybesubjectedtosuddenandunfortunateincidentsduring
operation.Typicalincidentsincludepowerloss,softwarecrash,oroperatingsystem
instability.Theseincidentsmaycausethecommunicationwiththetransceiverto
malfunction.
1ClicktheSetupicon.
ThisiconislocatedundertheMainmenu.ItisusedtoopentheSetup
menu.
Setupmenuonpage152
338106/C
107