User manual

Operationalprocedures
Important
TheASCIIdatagramwiththeexternalannotationmustbeconnectedtothesameserial
lineasthenavigationsystem.
Thefollowingtelegramsaresupported:
SimradATSAnnotationonpage280
Therststep(withsub-steps)inthisprocedureexplainshowtodothephysicalcabling
usingaseriallineoranEthernetconnection.Theremainingstepsdescribehowtosetup
theinterfaceintheES70software.
1ConnecttheES70totheperipheralsystemusingaserialline.
aLocateafreeserialportthatcanbeusedforthiscommunication.
bOntheseriallinesocketontheES70computer,connectanRS-232cableas
follows:
ReceivesignalRxonpin2.
TransmitsignalTxonpin3.
CommonGroundonpin5.
cOntheexternalsystem,wireasdescribedintherelevantdocumentation.
dEnsurethatthetotallengthoftheseriallinecabledoesnotexceed
approximately50meters.
Ifalongercableisrequired,youmayneedtousebufferampliersonthe
serialline.
2ClicktheSetupicon.
ThisiconislocatedundertheMainmenu.ItisusedtoopentheSetup
menu.
Setupmenuonpage152
3ClickAnnotationstoopentheAnnotationsdialog.
ThepurposeoftheAnnotationsdialogistoallowyoutoentercommentsand
annotationsintotheechograms.
Annotationsonpage189
4ClickPortsoselectcommunicationport.
5ClickSetupsodenethecommunicationparameters.
6Ifthedataowisoperational,closealldialogs.
338106/C
105