User manual

Operationalprocedures
12Checkthedataowontheinputcommunicationline.
Inordertomonitorthisdataow,theperipheralsystemmustbeactiveand
transmittinginformationtotheES70.
13Ifthedataowisoperational,closealldialogs.
Settinguptheinputfromananaloguetemperaturesensor
ThisprocedureexplainshowtosetuptheES70toreceivetemperatureinformation
throughtheanalogueinputontheGeneralPurposeTransceiver(GPT).
Ifmorethanonetransceiverisusedbytheechosoundersystem,asingletemperature
sensorisonlyconnectedtoonlyoneofthem.Ifyouhavemorethanonesensorand
severaltransceivers,youcanconnectonesensortoeachtransceiver,andtheninthe
Temperaturesensordialogselectwhichonetoread.
Therststep(withsub-steps)inthisprocedureexplainshowtodothephysicalcabling
usingaseriallineoranEthernetconnection.Theremainingstepsdescribehowtosetup
theinterfaceintheES70software.
1ConnectthetemperaturesensortotheES70system.
aOntheES70GeneralPurposeTransceiver,connectthepositivesignalfromthe
sensortopin4ontheAuxiliaryconnectorontheGeneralPurposeTransceiver.
bConnectthegroundsignalfromthetemperaturesensortopin17onthe
Auxiliaryconnector.
2OntheES70,accesstheInstallmenu,andopentheTemperaturesensordialog.
3ForSourceselection,selectAnaloginput.
4Selectwhichtransceiveryouhaveconnectedthetemperaturesensorto.
Whenthesensorisoperational,youwillbeabletofollowthetemperaturereadings
inthedialog.
Settingupthedepthoutputtoaperipheralsystem
Thisprocedureexplainshowtosetupaseriallinetoexportthisinformationtoa
peripheralsystem.
TheES70willoutputdepthinformationonseveraldifferentformats.
Thefollowingtelegramsaresupported:
DBSDepthbelowsurfaceonpage266
DBTDepthbelowtransduceronpage266
DPTDepthonpage267
SimradEK500Depthtelegramonpage273
Atlasdepthtelegramonpage281
PSIMDHBBottomhardnessandbiomassonpage278
338106/C