Unit installation

FS 70 Installation Instructions
974-24007001/4.1 33
4.2.6 Interconnect Cables Description
ID #
Application
Description
C1
Video Connection
Standard Video cable supplied with monitor
C2
Video Connection
Standard Video cable supplied with monitor
C3
AC Power Input
Standard 110/230Vac cable supplied with
the processor
C4
PS2 Mouse
Logitech Trackman Trackball-STO Mouse
C5
PS2 Keyboard
Mini Cherry Keyboard
C6
Ethernet 1 Connection
Cat 5 RJ45 Ethernet cable “Optional”
C7
Ethernet 2 Connection
Cat 5 RJ45 Ethernet cable “Optional”
C8
RS232 Com Port
RS 232 Cable not supplied “Optional”
C9
Ground Wire Connection
Ground wire Cable not supplied “Optional”
C10
FS 70 USB Port
Connection for USB/RS232 Converter
C11
FS 70 USB Port
Connection for USB/RS232 Converter
C12
FS 70 USB Port
Connection for USB FS 70 Security Key
4.2.7 Connection the USB Security Key “Dongle”
The security key “USB Dongle” is require to run the FS 70 host
software and must be connect the to a USB port located at the rear of
the processing Unit. Connect the key as indicated in the above DWG
located in paragraph 4.2.5.
NOTE: The security key “Dongle” is NOT a “Flash Memory
USB” stick.