Problem Action/Possible Cause
head is properly mounted in trawl
housing.
No Sensor Module Data
-No depth, temperature or catch
indication
Ensure sensor module connected
Ensure display of sensor data is
enabled
Problem can be in either the head or
the sensor module
If backup Vertical Head and/or
backup Sensor Module available,
swap out units to determine which is
faulty
Send faulty unit ashore for repair
Missing Sensor Module Data
-Depth and temperature present
-No catch indication at all (yellow
bars for eggs on net, then pink when
net starts to fill)
Ensure catch indication is enabled
Ensure catch sensor batteries are
properly charged
If the catch indication is enabled and
the batteries are properly charged
then the problem will be in the sensor
module
Send faulty unit ashore for repair
Sensor Module Catch Indication
-Depth and temperature present
-Catch Indication working but fires off
all the eggs at once (even channels
that aren’t in the water)
Caused by a power reset in the
sensor module; the power to the
sensor module is supplied by the
head
Can be caused by ship power
fluctuation
Normal (and acceptable) if the eggs
clear and return to normal indication
within 70-90 seconds
Not Normal if they won’t clear on
their own (unit has gone into
continuous reset)
You should not have to turn the
power off and then back on to get
rid of this problem
Sensor Module faulty; send
ashore for repair
Not Normal if the frequency of this
problem starts to occur more often,
even if they still clear on their own
Send sensor module ashore for
testing