User guide

901-10037001/1.1 FS 20/25 Operators Manual
Page 4.6 FS 20/25 Installation, System Set-Up and Test
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
serial “B” port at the rear of the processing unit. A standard 9-pin serial cable is
supplied with the TTM module.
If you require connecting a DGPS NMEA 183 output to the serial port at the rear of the
processing unit, you will have to install an addition serial card in the HP PC Processing
units. The recommended type of serial card to install and the installation procedure are
provided in Part 7 “Attachments”. Interconnect cable not supplied.
The pin connections for your DGPS input/output PC/RS232 are as follows:
Pin number “2” 232 Rx, Pin number “3” 232 Tx, and Pin number “5” GND.
Connect the security key “Dongle” to the parallel port. If you require connecting a
printer in the parallel port, just plug your printer into the “Dongle”.
Your FS 20/25 comes equipped with a Network LAN interface adapter card. The LAN
adapter supports both 10Mbit/s and 100Mbit/s operations and automatically detects
which network type is being used. The RJ-45 plugs into your FS 20/25 optional remote
workstation. LAN cables are not supplied with the system.
For additional information, please refer to the User’s Guide supplied with the system.
Warning!
Before applying the power to the processing unit, ensure that the
proper AC input voltage has been selected.