Installation manual

SimradES70
Procedure
1ClicktheOperationicon.
ThisiconislocatedundertheMainmenu.ItisusedtoopentheOperaiton
menu.
Operationmenuonpage109
2ClickNormalOperationtoopentheNormalOperationdialog.
ThepurposeoftheNormalOperationdialogistoofferyouanoverviewofthe
currenttransceiverparameters,andtoprovideyouwiththeabilitytochangethem.
3Fortherelevanttransducerchannel,setPower[W]torequestedvalue.
Outputpoweronpage125
4ClickOKtosavethecurrentsettingsandclosethedialog.
Adjustingthepulseduration(length)
Thisprocedureexplainshowtochangethepulselength(duration).
Tip
Thelengthofyourtransmittedpulseisveryimportanttohowyoucandetectsh.
Ashortpulsedurationgivesyouaveryneverticalresolution.Thisallowsyouto
detectscatteredsh,andyoucanndthosethatmovenearthebottom.
Alongpulsedurationthrowsalotmoreenergyintothewater,andthedigitallters
usedbythereceiverarenarrower.
TheselterswillreducetheES70'ssensitivityfornoise,butthelengthofthe
transmittedpulsewillgiveyoustrongerechoes.Withthelters,alongerpulse
durationwillprovidelongerrange,butreducedverticalresolution.
Procedure
1ClicktheOperationicon.
ThisiconislocatedundertheMainmenu.ItisusedtoopentheOperaiton
menu.
Operationmenuonpage109
2ClickNormalOperationtoopentheNormalOperationdialog.
ThepurposeoftheNormalOperationdialogistoofferyouanoverviewofthe
currenttransceiverparameters,andtoprovideyouwiththeabilitytochangethem.
3Fortherelevanttransducerchannel,setPulseLengthtorequestedvalue.
Forgeneraluse,werecommendthatthepulsedurationissettoAuto.
Pulsedurationonpage127
72
343539/C