Installation manual
SimradES70
Figure11Pulsedurationprinciples
(CD010217C)
C
1
2
A
B
D
1
2
A
B
Apulsedurationof1mScovers
1,5metersinthewater,and
thiscorrespondstoatarget
separationofapproximately
75cm.Thisisatypicalpulse
durationthatyoumaywelluse
downto250to300meters.
Ifyouworkindeeperwaters
usealongerpulseduration,
ifitisshallower,useashorter
pulseduration.Tryoutdifferent
values,andseekoutthepulse
durationthatprovidesyouwith
theclearestechopresentation
withminimumnoise,butwith
maximumshdetectionand
separation.
Theleftvesselusesalongpulseduration(C).Asyoucansee,thiscausestheechoes
fromthetwoshes(A)and(B)tomerge.Therightvesselusesashorterpulseduration,
andthetwosheswillthenappearastwoseparateechoesontheechogram.Thus,
shortpulseswillprovidethebestresolutionandseparationofindividualshes,butthe
echosounderismoresensitivetonoise.
Thespeedofsoundinwaterisapproximately1500m/s.Thelengthofa1mSsound
pulsewillthusbeapproximately1,5meter.Withtheechosounderyoucanthenadjust
thesoundpulsefrom7,5cm(0.05mS)to24m(16mS)dependingoftheoperational
frequency.Thisisanimportantfactorfortheappearanceofsingleshes.
•Whentheverticaldistancebetweentoshes,orthedistancebetweenashandthe
bottom,ismorethanthedistancecoveredbyahalfpulseduration,theechoeswillbe
presentedastwoseparateechoes.Theshabovethebottomwillbeidentied.
•Ifthedistancebetweentwoindividualshes,orthedistancebetweenasinglesh
andthebottom,islessthanthedistancecoveredbyahalfpulseduration,theecho
willbepresentedasoneecho.Theechofromtheshclosetothebottomwillbe
mergedwiththebottomecho.
Alloperationalfrequencieshavedifferentpulsedurations.Thedifferencebetweenfor
examplea50kHzanda38kHztransducerishowevernotlarge:
•A50kHztransducercanbeusedwithpulsedurationsfrom0,12mSto2mS
•A38kHztransducercanbeusedwithpulsedurationsfrom0,26mSto4mS.
Basically,boththesefrequencieswillprovideyouwiththesamedetectionability.A
50kHztransducermayprovidebetterresolutioninshallowwaters,whilethe38kHz
transducermayprovidelongerrangeondeeperwaters.Onthe38kHztransducerthe
shortestpulsedurationis0,26mS.Thisresultsina40cmsoundpulseanda20cm
shseparation.
InordertocontrolthepulsedurationontheSimradES70,usetheNormalOperation
functionontheOperationmenu.
128