Installation manual
SimradEK60
Seriallinesupport
The4-portserialboardsupportsthefollowingseriallineinterfaceformats:
•Port1:RS-232/422/485
•Port2:RS-232/422/485
•Port3:RS-422/485
•Port4:RS-422/485
Note
Bymanufacturerdefault,alltheseserialconnectionsaresettoRS-422format.Inorder
tochangethistoRS-232orRS-485format,dedicatedjumpersorDIPswitchesmustbe
changed.
Notethatonlyports1and2supportRS-232format.
JumperandDIPswitchsettings
Usethe10-pinjumperarraysandthetwoDIPswitchestosetports1and2toRS-232,
RS-422,orRS-485.UsethetwoDIPswitchestosetports3and4toRS-422orRS-485.
•RS–232:InordertousePort1(COM2)orPort2(COM3)asRS-232interfaces,the
relevantjumperarraysforPort1orPort2mustbemoved.Notethatports3and4
donotsupportRS-232format.
•RS-422:AllfourportscanbesettoRS-422usingthetwojumpersandtheright-hand
DIPswitchS2.
•RS-485:AllfourportscanbesettoRS-485usingthetwojumpersandtheright-hand
DIPswitchS2.Additionally,eachportcanbeselectedfora2-wireor4-wire
connectiontypeusingtheleft-handDIPswitchS1.
Figure5LocationofthejumpersandDIPswitches
AJumperforPort1interfacesetup
BJumperforPort2interfacesetup
CDIP-switchS1for2–wireor4–wiresetup(all
ports)
DDIP-switchS2forRS-422orRS-485selection
(allports)
20
359619/A