Installation manual

Simrad ES38-10
ES38–10 transducer connection
This is the termination of the transducer cable from the ES38–10
split-beam transducer to the transducer socket on the ES60 and
EK60 General Purpose Transceiver Unit (GPT). The other end of
the cable is permanently xed to the transducer.
All transducer cables must be run in steel conduits. Use a exible
conduit closer to the transceiver.
M
E
F
J
H
D
C
K
L
A
B
N
ES38-10
transducer cable
J
E
F
H
D
C
Junction Box (1:1)
(Optional)
GPT Transducer
socket
White
White
White
Black
Black
Black
Screen Connect to plug housing
W802-8
Rev.A
ES38-10 Transducer cable termination
FWD
Sections seen from top
of the transducer
1
2
3
1
2
3
There are four pairs in the transducer cable, each with one black
and one white cable. Each pair is marked with a small label
identifying the transducer section. Pair number 4 is not used.
Note
Thecablescreenmust not be connected to the ship’s ground
through the junction box.
The cable screen can be connected to the junction box chassis, but
the junction box chassis m
ust not be connected to ship’s ground.
36 305176/A