Installation manual
Operationalprocedures
Howtochooseanautomaticstartdepth
Thisprocedureexplainshowtoenableuseofthe
automaticstartdepthfunction.Thestartrangeis
controlledbytheStartRangebuttonontheMainmenu.
Note
TheAutomaticStartDepthfunctionwillonlyworkinsurfacerelatedechograms.
Example11AutomaticStartDepth
IfyousetRangeto20metersandenabletheAutomaticStartDepthfeature,
yourechogramwillalwaysbedrawntomakethebottomcontourappear
closetothebottomofyourechogrampresentation.Ifthewaterdepthexceeds
20meters,theES70willautomaticallymovethestartrangedown.Therange
iskept,butasthestartrangeismoved,thebottomcontourisstillvisible.
1ObservetheMainmenu.ItisnormallylocatedontherighthandsideoftheES70
presentation.
2ObservetheStartRangebutton.
3Clickthemiddleofthebuttontoopenit.
4ClicktoenableAutomaticStartDepth.
5Clickthemiddleofthebuttontocloseit.
Howtochoosetheverticalrange
TheverticalrangeiscontrolledbytheRangebutton
ontheMainmenu.
Example12StartRangeandRangeinbottomrelatedechogram
Inabottomechogram,settheStartRangevalueto–5meters.Thiswill
maketheechogramstartfrom5metersabovethebottom.SetRangetothe
5metersplus10=15meters.Theechogramwillnowshowtheareafrom
5metersabovethedepth,anddownto10meters“below”thebottom.The
bottomcontourwillappearasaatline.
Twomethodscanbeused.
1Method1:
aClick[+]or[-]toadjusttherangemanually.
343539/B
89