Installation manual

Gettingstarted
3ObservetheRangebuttonontheMainmenu.
TheRangefunctionallowsyoutospecifytheverticalrangeofthewatercolumn
coveredbytheechogram.Therangeisdenedfromaselectedstartrange,and
downtoavaluebeneaththecurrentbottomdepth.Thevalueshownandselectedis
bydefaultappliedonlytothecurrentlyselectedechogram.
4ObservetheStartRangebuttonontheMainmenu.
TheStartRangefunctionallowsyoutospecifythestartdepthoftheechogram,that
isfromwhichdepthinthewatercolumnthepresentationshallstart.Thevalue
shownandselectedisappliedtothecurrentlyselectedechogramtype.Inasurface
relatedechogram,youcanclickAutomaticStartDepthtoallowtheES70toselect
thestartrangeautomatically.
Example2StartRangeinasurfacerelatedechogram
Inasurfaceechogram,settheStartRangevalueto0meters.This
willmaketheechogramstartfromtheseasurface(providedthatthe
transduceroffsethasbeendened).SetRangetothecurrentdepthplus
20meters.Theechogramwillnowshowtheareafromtheseasurface
anddownto20meters“below”thebottom.Thebottomcontouris
easilydetectedwhenthedepthchanges.
Example3StartRangeinasurfaceechogram
Inasurfaceechogram,settheStartRangevalueto10meters.Thiswill
maketheechogramstartfrom10metersbelowtheseasurface(provided
thatthetransduceroffsethasbeendened).SetRangetothecurrent
depthplus20meters.Theechogramwillnowshowtheareafrom10
metersbelowtheseasurface,anddownto10meters“below”the
bottom.Thebottomcontouriseasilydetectedwhenthedepthchanges.
5SetRangetoAuto,andsetStartRangeto0.
Observethechangesmadetothesurfacerelatedechogram.
6Clickinabottomrelatedechogramtomakeit“active”.
7ObservetheRangeandStartRangebuttonsontheMainmenu.
Example4StartRangeandRangeinbottomrelatedechogram
Inabottomechogram,settheStartRangevalueto–5meters.Thiswill
maketheechogramstartfrom5metersabovethebottom.SetRangeto
the5metersplus10=15meters.Theechogramwillnowshowthearea
from5metersabovethedepth,anddownto10meters“below”the
bottom.Thebottomcontourwillappearasaatline.
343539/B
31