Installation manual
SimradES70
5ClicktheVerticaltab.Observethattheechogramchannelsareshownvertically.
6Clickononeoftheechograms.
Observethattheechogramthenappearswithathickborderline.Theechogramyou
haveselectedisnowthe“active”echogram.AnychangesmadeintheEchogram
dialogwillbydefaultonlyapplytothisechogram.
7OntheActivemenu,clickEchogram.
ObservethattheEchogramdialogopens.Thisdialogisusedtocontrolthe
appearanceoftheactiveechogram.
8IntheEchogramdialog,checkthattheLinestabisshown.
TheLinestabintheEchogramdialogallowsyoutochangetheappearanceofthe
bottomline.Youcanaddanextrabottomline,andinadditiontothisyoucanenable
eitherawhitelineorahardnessindicatorline.Thetaboffersseveralhorizontal
informationlines,andyoucanchoosetheverticalscaleoftheechogram.Finally,
theLinestabofferstimeordistancemarkers,andyoucanenableannotations.
9ClickBottomlineandWhitelinetoenablethese.Observethechangesonthe
echogram.
10ClicktheEchogramtab.
TheEchogramtabintheEchogramdialogallowsyoutoselectwhichTVGcurveto
usefortheechogram.Youcanchoosefromseveralstandardcurves,ormakeyour
own.Thetabalsoallowsyoutochoosewhichtypeofechogramyouwishtodisplay.
→AboutTVGgainonpage109
11ChangetheEchogramTypetoseethevariations.
12ClicktheHorizontalAxistab.
13Trythevariousoptionstoseethevariationsontheechogram.
14ClickOKtosavethecurrentsettingsandclosethedialog.
Howtochecktherangesettings
Thisproceduredescribeshowtocheckandadjusttheverticalrangesettings.
1Observetheverticalrangeoftheechograms.
Notethattheverticalrangeissetupdifferentlydependingontheechogramtype.
2Clickinasurfacerelatedechogramtomakeit“active”.
30
343539/B