Installation manual
Gettingstarted
Theechogramisrelatedtotheseasurface.Startdepth(upperechogram
boundary)andverticalrange(acrossechogram)aremanuallyselectedbythe
StartDepthandRangebuttonsontheMainmenu.
Thebiomassisautomaticallycalculatedbasedonchoicesyoumakeinthe
CalculationIntervaldialog;withinagiventimeframe,adenednumberof
pings,oraportionoftheechogramview.Thedataisthentakenfromanecho
areastartingimmediatelyafterthetransmitpulse,andendingjustoverthe
detecteddepth.Ifyouhavelimitedyourverticalrange(usingtheRangeand
StartRangesettings),theresultingareaisusedforthebiomasscalculation.If
theseabedisclearlydenedwithauniquebottomdetection,thebottomecho
willn
o t beincludedinthecalculations.Therefore,ifyouswitchthebottom
detectoroff,thebottomechowillbeincludedinthecalculation.
→Biomassinformationpaneonpage59
bBottom
Theechogramisrelatedtothedetectedbottom.Stopdepth(lowerechogram
boundary)andverticalrangearemanuallyselectedbytheStartDepthand
RangebuttonsontheMainmenu.Theechogramisonlydrawnforpingshaving
asuccessfulbottomdetection.
ThebiomasscalculationismadeinthesamewayasforSurfaceechograms.
cPelagic
ThisechogramisnearlyidenticaltotheSurfaceechogram.However,the
biomassiscalculatedinadifferentmanner.
Thebiomasscalculationsarenotrestrictedbythebottomdetection.This
meansthatthebottomechowillbeincludedincalculationsifitappearswithin
thechosenrange.
Example1Biomasscalculation
Ifyouareinvestigatingalargeschoolofpelagicsh,setthe
StartRangeandRangetoenclosetheschool.Iftheschoolis
largeenough,aSurfaceechogrammaymistakeitforbottom,and
thebiomassreadingswillbewrong.ThePelagicechogramwill
howeverdisregardthebottomdetection,andgiveacorrectestimate
ofthebiomass.
dTrawl
Thisechogramcoverstheverticalopeningofthetrawl.
Theechogramisonlydrawnwhentrawlpositioninformationisavailable.
ThebiomasscalculationismadeinthesamewayasforSurfaceechograms.
3Movethecursorovertheechogram.
Observethatarectangular“tooltip”labelisshown.Itprovidesinformationabout
theechoesatthecursor’spresentposition.Whichinformationtoincludeinthelabel
isdenedintheDisplayOptionsdialog.
4ClicktheHorizontaltab.Observethattheechogramchannelsareshownhorizontally.
343539/B
29