Installation manual
Transducerhandlingandmaintenance
Figure6Exampleofuse
(CD017020C)
Note
Inthecaseoftappingthroughholesitisimportantthatthe
proleoftheEmugeself-lockthreadsisinthecorrectdirection
comparedwiththeenteringdirectionofthebolt.
Gauge
UseEmugeself-lockgauges.Notethatthegaugemustbeused
inthecorrectdirection.
Self-locktapsprovidedbySimrad
Thefollowingself-locktapsareonstockatSimrad,andcanbe
orderedfromus.
Threads
Drilldiameterfor
threads
Part.no
M6ø5.2700-078838
M8ø7.0700-078531
M10ø8.8700-078408
M12ø10.7700-078409
M16ø14.5700-078410
Supplierandmanufacturer
Norwegiansupplieris:
TingstadAS,P.O.Box83,Kalbakken,0902Oslo,Norway
h
t t p : / / w w w . t i n g s t a d . n o
Manufactureris:
EMUGE-WerkRichardGlimpel,NurnbergerStrasse96-100,
D-90607Lauf,Germany
h
t t p : / / w w w . e m u g e . d e
330254/A
35